Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.538
Filter
1.
Acta ortop. bras ; 32(1): e277177, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550005

ABSTRACT

ABSTRACT Introduction: Legg-Calvé-Perthes disease (LCPD) is the idiopathic osteonecrosis of the capital femoral epiphysis in children. It is a self-healing condition, and the morphology of the hip may vary according to the severity of the disease, among several other factors. The treatment focuses on attempts to prevent femoral head collapse, obtain functional hip motion recovery, and reduce pain. Osteochondritis Dissecans (OCD) of the femoral head has been reported in 2% to 7% of patients diagnosed with healed LCPD. Although OCD may remain asymptomatic, the osteochondral fragment has the potential to become unstable, evolving into symptoms of pain, locking, catching, and snapping. Case report: We present a case report of a ten-year-old boy with an OCD lesion following LCPD who underwent effective osteochondral fixation through the surgical hip dislocation approach. The patient evolved to excellent functional recovery at 1 year post-operatively. Discussion: The surgical hip dislocation approach allows anatomical fixation of the OCD fragment, as well as improvement of hip biomechanics, decreasing pain, improving range of motion and joint congruency, and preserving the native articular cartilage. It also gives the surgeon the opportunity to assess hip stability, femoroacetabular impingement and labral tears, allowing a wide variety of options for the treatment of the healed LCPD. Level of Evidence IV; Type of study Case Report.


RESUMO Introdução: A Doença de Legg-Calvé-Perthes (DLCP) é a osteonecrose idiopática da epífise femoral proximal em crianças. É uma condição auto resolutiva, porém a morfologia final do quadril pode variar de acordo com a gravidade da doença. O tratamento concentra-se na tentativa de prevenir o colapso da cabeça femoral, obtendo recuperação funcional do movimento do quadril e redução da dor. A osteocondrite dissecante (OCD) da cabeça femoral foi relatada em 2% a 7% dos pacientes diagnosticados com DLCP já curada. Embora a OCD possa permanecer assintomática, o fragmento osteocondral tem potencial para se tornar instável, evoluindo para sintomas de dor, bloqueio, impacto e estalido. Relato de caso: Apresentamos o relato de caso de um menino de 10 anos com OCD da cabeça femoral após DLCP, submetido à fixação osteocondral do fragmento por meio da abordagem cirúrgica de luxação do quadril. O paciente evoluiu com excelente recuperação funcional 1 ano após a cirurgia. Discussão: A abordagem cirúrgica da luxação do quadril permite a fixação anatômica do fragmento da OCD, bem como a melhora da biomecânica do quadril, diminuindo a dor, melhorando a amplitude de movimento e a congruência articular e preservando a cartilagem articular nativa. Também dá ao cirurgião a oportunidade de avaliar a estabilidade do quadril, impacto femoroacetabular e lesões labrais, permitindo uma ampla variedade de opções para o tratamento das sequelas da DLCP. Nível de evidência IV; tipo de estudo Relato de Casos.

2.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 57-63, 2024.
Article in Chinese | WPRIM | ID: wpr-1003446

ABSTRACT

Objective@#To investigate the effect of the socket-shield technique (SST) concurrent with immediate implant placement and provisionalization (IIPP) in the aesthetic restoration of anterior teeth.@*Methods@#A case of maxillary anterior tooth stumps with a thin labial bone wall was treated with SST for preservation of labial soft and hard tissue fullness, combined with an immediate implant placement and immediate provisional crown for restoring the shape of the tooth and gingival molding@*Results@#Immediate implant placement and provisionalization restored the morphology and function of the affected tooth in the shortest possible time. The patient's labial soft and hard tissue contours in the affected tooth area were well preserved in the 18-month follow-up after the application of the SST, which presented a better aesthetic result. The literature review indicates that the indications for SST are unrestorable maxillary anterior teeth, whose dental, periodontal and periapical tissues are healthy and intact. In the esthetic zone, root shielding is effective in maintaining the soft and hard tissue contour on the labial side of the implant. However, there is no consensus on the technical details of SST, such as the ideal coronal height and thickness of the shield, and the management of the gap between the shield and the implant. Thus, more clinical studies and histologic evidence are needed to provide a reference for clinical decision-making. In addition, digital technology can improve the accuracy of implant placement and shield preparation.@*Conclusion@#The correct application of SST combined with IIPP in the esthetic zone can ensure esthetic results. However, more high-quality evidence-based medical evidence is needed for its long-term efficacy, and indications should be strictly controlled during clinical application.

3.
Int. j. morphol ; 41(5): 1508-1512, oct. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1521014

ABSTRACT

SUMMARY: Distal radius fractures are the most common fractures of the upper limb. The most commonly used method in the repair of these fractures is volar locking plates. Recently, the frequency of removal of volar locking plates after surgery has increased. There are many factors in its reduction. Anatomically, incompatibility of the distal end of the radius with volar locking plates is one of them. In previous studies, different volar cortical angle (VCA) values were found in other races. For this reason, this study aimed to determine the mean values by making VCA measurements of the Anatolian population. The study was designed retrospectively. In the study, measurements were made on computed tomography (CT) images of the distal end of the radius of 53 men and 28 women. Radial width, intermediate volar angle, and radial volar angle were measured in the images. On average, the radius width was 23.35±1.96 mm, and the intermediate volar angle was 26.02±.3.83°, radial volar angle was 24±3.07°. Radial width, intermediate volar angle, and radial volar angle differed significantly by gender (p<0.001). A significant correlation was found between radius width, intermediate volar angle, and radial volar angle values (p<0.001). It has been determined that the Anatolian population has a different VCA value than the European, Asian, and other populations. When using volar locking plates in distal radius fracture surgery, volar locking plates should be selected by considering the average values of the races.


Las fracturas del radio distal son las fracturas más comunes del miembro superior. El método más utilizado en la reparación de estas fracturas son las placas de bloqueo volar. Recientemente, ha aumentado la frecuencia de extracción de placas de bloqueo volar después de la cirugía. Existen muchos factores en su reducción y anatómicamente, la incompatibilidad de la extremidad distal del radio con las placas de bloqueo volar es una de ellas. En estudios anteriores, se encontraron diferentes valores del ángulo cortical volar (VCA) en otras grupos. Por esta razón, este estudio tuvo como objetivo determinar los valores medios, realizando mediciones de VCA de la población de Anatolia. El estudio fue diseñado de manera retrospectiva. En el estudio, se realizaron mediciones en imágenes de tomografía computarizada (TC) de la extremidad distal del radio de 53 hombres y 28 mujeres. En las imágenes se midieron el ancho radial, el ángulo volar intermedio y el ángulo volar radial. En promedio, el ancho del radio fue de 23,35 ± 1,96 mm, el ángulo volar intermedio fue de 26,02 ± 3,83° y el ángulo volar radial fue de 24 ± 3,07°. El ancho radial, el ángulo volar intermedio y el ángulo volar radial difirieron significativamente según el sexo (p<0,001). Se encontró una correlación significativa entre los valores del ancho del radio, el ángulo volar intermedio y el ángulo volar radial (p<0,001). Se ha determinado que la población de Anatolia tiene un valor de VCA diferente al de las poblaciones europeas, asiáticas y otras. Cuando se utilizan placas de bloqueo volar en cirugía de fractura de la extremidad distal del radio, las placas deben seleccionarse considerando los valores promedio de los individuos de diferentes grupos.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Radius/diagnostic imaging , Wrist/diagnostic imaging , Radius/anatomy & histology , Turkey , Wrist/anatomy & histology , Tomography, X-Ray Computed , Retrospective Studies
4.
Int. j. morphol ; 41(4): 1135-1145, ago. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1514341

ABSTRACT

SUMMARY: The human soleus muscle has attracted attention in the fields of sport science, rehabilitation medicine, etc. for improving exercise performance in training, preventing injuries, and rehabilitation. The sagittal tendon plate of the soleus muscle is particularly important in rehabilitation. Few studies, however, have evaluated the shape of the sagittal tendon plate in the human soleus muscle in detail and attempted to classify its variations based on its morphology. In this study, we conducted a detailed analysis of the morphology of the sagittal tendon plates in soleus muscle specimens from Japanese cadavers and constructed a morphology-based classification system and evaluated their frequencies of occurrence. First, the specimens were divided into those with a sagittal tendon plate that was visible on the anterior surface (pennate muscle group) and those without (non-pennate muscle group). Next, based on the "number" and "breadth" of the sagittal tendon plates, the pennate muscle group specimens were further classified into four classes: Class I (one tendon, thin), Class II (one tendon, slightly broad), Class III (one tendon, very broad), and Class IV (two tendons, thin). Subsequently, the specimens were further divided into three types based on the position where the sagittal tendon plate joined the Achilles tendon: median tendon type, lateral tendon type, and medial tendon type (a total 13 divisions). When 458 Japanese soleus muscle specimens were classified into these divisions, the occurrence frequencies of Class I-IV were 80.57 %, 4.59 %, 5.46 %, and 1.09 %, respectively. In Class I, the median tendon type was more frequent than the lateral and medial tendon types, accounting for 48.47 % overall. The classification types of the sagittal tendon plate and their respective occurrence frequencies shown in this study are expected to serve as fundamental data in implementing rehabilitation of soleus muscle.


El músculo sóleo humano ha atraído la atención de la ciencia del deporte, la medicina de rehabilitación, etc. para mejorar el rendimiento del ejercicio en el entrenamiento, prevenir las lesiones y rehabilitación. La lámina tendinosa sagital del músculo sóleo es particularmente importante en la rehabilitación. Sin embargo, pocos estudios han evaluado en detalle la forma de la placa lámina sagital en el músculo sóleo humano y han intentado clasificar sus variaciones en función de su morfología. Realizamos un análisis detallado de la morfología de las láminas de los tendones sagitales en muestras de músculo sóleo de cadáveres japoneses y construimos un sistema de clasificación basado en la morfología y, además, evaluamos su frecuencia de aparición. Los especímenes se dividieron en aquellos con una lámina de tendón sagital que era visible en la superficie anterior (grupo muscular pennado) y aquellos sin (grupo muscular no pennado). A continuación, según el "número" y el "ancho" de las láminas de los tendones sagitales, las muestras del grupo de músculos pennados se clasificaron en cuatro clases: Clase I (un tendón, delgado), Clase II (un tendón, ligeramente ancho), Clase III (un tendón, muy ancho) y Clase IV (dos tendones delgados). Posteriormente, las muestras se dividieron en tres tipos, según la posición donde la lámina del tendón sagital se unía al tendón calcáneo: tipo de tendón mediano, tipo de tendón lateral y tipo de tendón medial (un total de 13 divisiones). En estas divisiones se clasificaron 458 especímenes de músculo sóleo de indiviuos japoneses, las frecuencias de ocurrencia de Clase I-IV fueron 80,57 %, 4,59 %, 5,46 % y 1,09 %, respectivamente. En la Clase I, el tipo de tendón mediano era más frecuente que los tipos de tendón lateral y medial, representando el 48,47 % del total. Se espera que los tipos de clasificación de la lámina del tendón sagital y sus respectivas frecuencias de aparición, que se reportan en este estudio, sirvan como datos fundamentales para implementar la rehabilitación del músculo sóleo.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Tendons/anatomy & histology , Muscle, Skeletal/anatomy & histology , Cadaver , Japan
5.
Kinesiologia ; 42(2): 127-131, 20230615.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552472

ABSTRACT

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

6.
Article | IMSEAR | ID: sea-221474

ABSTRACT

Background- Fractures of distal femur are one of the most prevalent fractures encountered in high-velocity trauma which are associated with high morbidity and mortality if not managed well. The isolated fracture can itself lead to complications such as Acute Respiratory Distress and pulmonary embolism. This neccesitaties early stabilisation of the fractures. Open reduction and internal fixation (ORIF) with locking compression plate is the treatment of choice for closed fractures of the distal femur. Distal femur anatomic contoured locking compression plate (LCP) has shown to give one of the best results regarding recovery, fracture union, return to work and the functional outcome. We present our experience of management of distal femur fracture at our centre. Study Material and Methodsdone on 36 patients, (NEER'S Classification) age range of 18 to 70 years (irrespective of their sex), were subjected to fixation by locking compression plate after obtaining thorough written informed consent. The observational study was carried at our institute between June 2021 to June 2022 Patients of both gender who were skeletally mature are taken into the study. In 61.5% of patients up to 50 years old and in Results40% of patients older than 50 years, the functional evaluation of LCP using Neers criteria was excellent. There was no statistically significant (p>0.05) difference in patients' functional status according to their age group who had distal femur fractures, which were stabilise by LCP. For supracondylar femur fractures, locking compression plates is a safe technique that has a good functional outcome, early clinical and radiographic union, and few complications.

7.
Article | IMSEAR | ID: sea-220101

ABSTRACT

Reconstruction plates with or without bone grafts are used to restore mandibular continuity, form and function following segmental resection of mandible. Fracture of reconstruction plate is observed in 2.9 % to 10% of cases reported in the literature excluding other complications. In this case, we report the fracture of stainless steel reconstruction plate used without bone graft and its management using locking reconstruction plate with non vascularised iliac crest graft following removal of the fractured plate. Review of literature describing incidence, pattern and causes of reconstruction plate fracture and its management is discussed.

8.
Rev. bras. ortop ; 58(2): 191-198, Mar.-Apr. 2023. graf
Article in English | LILACS | ID: biblio-1449794

ABSTRACT

Abstract Historically, surgeries on the immature skeleton were reserved for open or articular fractures. In recent years, the improvement in the quality and safety of anesthesia, new imaging equipment, implants designed especially for pediatric fractures, associated with the possibility of shorter hospitalization time and rapid return to social life has demonstrated a new tendency to evaluate and treat fractures in children. The purpose of this update article is to answer the following questions: (1) Are we really turning more surgical in addressing fractures in children? (2) If this is true, is this surgical conduct based on scientific evidence? In fact, in recent decades, the medical literature demonstrates articles that support better evolution of fractures in children with surgical treatment. In the upper limbs, this is very evident in the systematization of the reduction and percutaneous fixation of supracondylar fractures of the humerus and fractures of the forearm bones. In the lower limbs, the same occurs with diaphyseal fractures of the femur and tibia. However, there are gaps in the literature. The available published studies show low scientific evidence. Thus, it can be inferred that, even though the surgical approach is more present, the treatment of pediatric fractures should always be individualized and conducted according to the knowledge and experience of the professional physician, taking into account the presence of technological resources available for the care of the small patient. All possibilities, non-surgical and/or surgical, should be included, always instituting actions based on science and in agreement with the family's wishes.


Resumo Historicamente, as cirurgias no esqueleto imaturo eram reservadas às fraturas expostas ou articulares. Nos últimos anos, a melhora na qualidade e segurança das anestesias, novos equipamentos de imagem, implantes desenhados especialmente para fraturas pediátricas, associados à possibilidade de menor tempo de hospitalização e rápido retorno ao convívio social vêm demonstrando uma nova tendência de avaliar e tratar fraturas na criança. O objetivo deste artigo de atualização é responder às seguintes questões: (1) estamos realmente ficando mais cirúrgicos na abordagem das fraturas em crianças? (2) Caso isto seja verdadeiro, esta conduta cirúrgica está baseada em evidências científicas? De fato, nas últimas décadas, a literatura médica demonstra artigos que suportam melhor evolução das fraturas na criança com o tratamento cirúrgico. Nos membros superiores, isto fica muito evidente na sistematização da redução e fixação percutânea das fraturas supracondilianas do úmero e das fraturas de ossos do antebraço. Nos membros inferiores, o mesmo ocorre com fraturas diafisárias do fêmur e tíbia. No entanto, há lacunas na literatura. Os estudos publicados são geralmente com baixa evidência científica. Assim, pode-se deduzir que, mesmo sendo a abordagem cirúrgica mais presente, o tratamento de fraturas pediátricas deve ser sempre individualizado e conduzido de acordo com o conhecimento e experiência do médico profissional, levando em conta a presença de recursos tecnológicos disponíveis para o atendimento do pequeno paciente. Deve-se incluir todas as possibilidades, não cirúrgicas e/ou cirúrgicas, sempre instituindo ações baseadas na ciência e em concordância com os anseios da família.


Subject(s)
Humans , Child, Preschool , Child , Fractures, Bone , Salter-Harris Fractures , Fracture Fixation, Internal , Growth Plate/surgery
9.
Article | IMSEAR | ID: sea-217950

ABSTRACT

Background: Pain is a common stimulus that induces anxiety in both Animals and human beings. Aim and Objective: We have undertaken this study to evaluate the induction of anxiety in Wistar rats using hot plate method. Materials and Methods: 24 Wistar rats of either gender were used. Elevated plus maze (EPM) and light and dark arena (LDA) were used to evaluate the anxiety and hot plate analgesiometer was used to induce anxiety. After baseline reading from EPM and LDA, the Wistar rats were exposed to the hot plate and then evaluated for the induction of the anxiety behavior. Results: After exposing to the hot plate, the ratio of time spent in the open arms to the time spent on the closed arms was decreased from 0.027 to 0.010 and also the ratio of time spent on the light chamber to the time spent on the dark chamber was decreased from 0.093 to 0.012. Hot plate method has shown statistical significant induction of anxiety as evaluated by EPM and also LDA. Conclusion: Hot plate method is a good intervention to induce anxiety in Wistar rats. Instead of injecting drugs that causes anxiety to explore the anxiolytic effects of the drugs the hot plate analgesiometer method is a good alternative.

10.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420574

ABSTRACT

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

11.
Chinese Journal of Orthopaedic Trauma ; (12): 635-639, 2023.
Article in Chinese | WPRIM | ID: wpr-992760

ABSTRACT

Objective:To evaluate the minimally invasive fixation with a locking plate via the tarsal sinus approach in the surgical treatment of Sanders Ⅱ and Ⅲ calcaneal fractures.Methods:A retrospective study was conducted to analyze the 65 patients who had been surgically treated for Sanders Ⅱ and Ⅲ calcaneal fractures at Department of Foot and Ankle Surgery, Binzhou Medical College Hospital from April, 2019 to September, 2020. There are 44 males and 21 females with an age of (42.5±10.4) years, and 46 Sanders type Ⅱ fractures and 19 Sanders type Ⅲ ones. The patients were divided into group L and group S according to surgical methods. Group S of 35 cases was fixated with a minimally invasive locking plate through the tarsal sinus incision while group L of 30 cases fixated with a locking plate through the L-shaped incision. The 2 groups were compared in terms of waiting time before surgery, surgical time, hospital stay, intraoperative bleeding, visual analogue scale (VAS) at 3 days after surgery, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score at 1 year after surgery, excellent and good rate by the Maryland foot function score, B?hler angle, Gissane angle, varus angle, and complications.Results:There was no significant difference in the general data before surgery between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (13.3±1.6) months after surgery. The waiting time before surgery [(2.8±1.8) d], surgical time [(80.7±9.9) min], hospital stay [(6.7±1.9) d], intraoperative bleeding [(54.3±14.2) mL], and VAS at 3 days after surgery [6 (5, 7) points] in group S were all significantly less or lower than those in group L [(8.2±2.8) d, (105.0±15.7) min, (14.6±3.4) d, (74.3±12.8) mL, and 7 (6, 8) points] (all P<0.05). At one year after surgery, the AOFAS ankle-hindfoot score [(90.1±3.5) points] in group S was significantly higher than that in group L [(83.5±6.7) points] ( P<0.05), but there was no statistically significant difference in the excellent and good rate by the Maryland foot function score between the 2 groups [91.4% (32/35) versus 86.7% (26/30)] ( P=0.695). The B?hler angle, Gissane angle, and varus angle were significantly improved in all patients one year after surgery compared with the values before surgery ( P<0.05), but there were no statistically significant differences within either group or between the 2 groups at 3 days or 1 year after surgery ( P>0.05). Peroneal muscle pain was reported in 1 case in group S; there were 2 cases of skin necrosis, 1 case of incision hematoma and 1 case of sural nerve injury in group L. Conclusion:The minimally invasive fixation with a locking plate via the tarsal sinus approach is an effective treatment for Sanders Ⅱ and Ⅲ calcaneal fractures.

12.
Chinese Journal of Orthopaedic Trauma ; (12): 422-426, 2023.
Article in Chinese | WPRIM | ID: wpr-992728

ABSTRACT

Objective:To evaluate the radiological and clinical outcomes of the aged patients with unstable proximal humeral fracture (UPHF) treated with a locking plate and an intramedullary titanium mesh.Methods:A retrospective study was conducted to analyze the 43 aged patients with UPHF who had been admitted to Department of Orthopedics, Zhongda Hospital Affiliated to Southeast University from January 2017 to July 2019. There were 13 males and 30 females with an age of (71.3±10.3) years (from 60 to 83 years). All patients were treated with a locking plate and an intramedullary titanium mesh to support. The postoperative imaging measurements included changes in humeral head height (HHH) and neck-shaft angle (NSA) (the difference between 3 years after surgery and the second day after surgery, taken as an absolute value); the postoperative clinical measurements included visual analogue scale (VAS), range of shoulder motion, Constant-Murley shoulder functional score (Constant score), American Shoulder and Elbow Surgeons (ASES) score, and incidence of complications.Results:All patients were followed up for (39.2±2.3) months after surgery. The change in HHH at 3 years after surgery was (1.5±1.1) mm, and the change in NSA at 3 years after surgery 3.3°±2.6°. At 3 years after surgery, the VAS score was (2.2±1.3) points, the Constant score (79.2±9.1) points, and the ASES score (78.9±9.2) points; the range of forward extension was 143.2°±20.8°, the range of outward extension 139.3°±23.1°, and the range of outward rotation 55.1°±4.7°. Complications after surgery were found in 6 patients, including humeral head necrosis in 2 cases, ectopic ossification in 1 case, and infection in 3 cases.Conclusion:In the treatment of the aged patients with UPHF, a locking plate combined with an intramedullary titanium mesh can help to restore the medial column support, leading to fine radiological and clinical outcomes.

13.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 375-378, 2023.
Article in Chinese | WPRIM | ID: wpr-991757

ABSTRACT

Objective:To investigate the efficacy of a proximal femoral locking plate (LPFP) versus a proximal femoral anti-rotation intramedullary nail (PFNA) in the treatment of femoral intertrochanteric fractures in older adult patients. Methods:A total of 130 older adult patients with femoral intertrochanteric fractures who received treatment in Linghu People's Hospital of Huzhou from May 2017 to June 2020 were included in this study. They were randomly assigned to undergo treatment with either a PFNA (observation group, n = 65) or an LPFP (control group, n = 65). Intraoperative blood loss, incision length, operative time, and time to fracture healing were determined in each group. At 1, 3, and 6 months after surgery, the Harris hip score was used to evaluate hip joint recovery. Coxa vara, incision infection, and internal fixation loosening were compared between the two groups. Results:Intraoperative blood loss in the observation group was less than that in the control group [(189.26 ± 48.15) mL vs. (96.47 ± 40.21) mL, t = -11.93, P < 0.001]. Incision length, operative time, and time to fracture healing in the observation group were significantly shorter than those in the control group [(4.03 ± 1.48) cm vs. (12.16 ± 1.55) cm, (72.13 ± 28.75) minutes vs. (120.34 ± 29.01) minutes, (9.89 ± 1.52) weeks vs. (13.63 ± 1.74) weeks, t = -30.59, -9.52, -13.05, all P < 0.001]. At 1 month after surgery, there was no significant difference in Harris hip score between the two groups ( t = 1.28, P > 0.05). At 3 and 6 months after surgery, the Harris hip score gradually increased in the control and observation groups ( F = 13.44, 8.26, both P < 0.001). At 3 and 6 months after surgery, Harris hip scores in the observation group were significantly higher than those in the control group [(85.17 ± 4.29) points vs. (79.50 ± 4.12) points, (95.30 ± 1.04) points vs. (87.69 ± 1.25) points, t = 7.69, 37.73, both P < 0.001]. The incidence of complications in the observation group was significantly lower than that in the control group [1.54% (1/65) vs. 10.77% (7/65), χ2 = 4.80, P = 0.029). Conclusion:Compared with LPFP, PFNA can effectively reduce intraoperative blood loss in older adult patients with femoral intertrochanteric fractures, accelerate the progress of fracture healing, promote the recovery of the hip joint, and has fewer complications. Therefore, PFNA is worthy of popularization.

14.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 559-566, 2023.
Article in Chinese | WPRIM | ID: wpr-972227

ABSTRACT

Objective @#To investigate the clinical efficacy and application value of an improved 3D-printed guide plate for the treatment of primary trigeminal neuralgia (PTN) by percutaneous microballoon compression (PMC). @*Methods @# This prospective study included 42 patients with primary trigeminal neuralgia treated at the Department of Stomatology, Xuzhou Central Hospital, from September 2019 to January 2022. The group was divided by the random number table method into the experimental group (adopting 3D printing technology to make guide plates to guide the puncture, 22 cases) and the control group (adopting the traditional Hartel anterior approach to position the puncture, 20 cases). The intraoperative success rate of the first puncture, puncture time, operative time, radiation exposure of patients and postoperative complications were compared between the two groups. Postoperative Barrow Neurological Institute Scale (BNI) scores, facial numbness, diminished corneal reflexes and chewing weakness were recorded. The t-test, rank-sum test and chi-square test were used for statistical analysis, with P<0.05 indicating a statistically significant difference. @*Results @#The experimental group was significantly better than the control group in terms of the success rate of the first puncture (χ2 = 21.51, P<0.001), puncture time (Z = -5.51, P<0.001), operative time (t = 9.37, P<0.001), and the number of C-arm scans (Z = -4.59, P<0.001). Postoperative BNI scores of the experimental group included 21 cases of grade Ⅰ (91.5%) and 1 case of grade Ⅱ, while the control group included 17 cases of grade Ⅰ (85.0%), 2 cases of grade Ⅱ (10.0%) and 1 case of grade Ⅲ (5.0%), with no statistical significance (P>0.05). In the experimental group, 16 patients had postoperative masseter weakness, 1 had keratitis and 10 had perilabial herpes, while in the control group, 18 patients had postoperative masseter weakness, 2 had keratitis, 11 had perilabial herpes and 1 had monocular blindness. There was no significant difference in postoperative complications between the two groups (P>0.05). At 12 months of follow-up, there was no recurrence in either the experimental or control group. @* Conclusions @#3D digital guide plate-guided percutaneous microballoon compression for primary trigeminal neuralgia can improve the accuracy and safety of puncture to a certain extent, obviously shorten the operation time, reduce radiation exposure of the patients, improve the success rate of the operation, meaning it has a high clinical application value.

15.
Chinese Journal of Digestive Surgery ; (12): 489-496, 2023.
Article in Chinese | WPRIM | ID: wpr-990665

ABSTRACT

Objective:To investigate the application value of cystic plate approach (CPA) for extrahepatic right hepatic pedicle dissection in minimally invasive anatomical hepatectomy (MIALR).Methods:The retrospective cohort study was conducted. The clinicopathological data of 42 patients with primary liver cancer who underwent laparoscopic right hemi-hepatectomy in Nanfang Hospital of Southern Medical University from August 2020 to August 2022 were collected. There were 36 males and 6 females, aged (55±13)years. Of the 42 patients, 25 cases undergoing CPA for extrahepatic right hepatic pedicle dissection were divided into the CPA group, and 17 cases undergoing traditional approach for extrahepatic right hepatic pedicle dissection were divided into the traditional approach group. Observation indicators: (1) surgical situations; (2) postoperative situations. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the t test. Measurement data with skewed distribution were represented as M( IQR), and comparison between groups was conducted using the Mann-Whitney U test. Count data were described as absolute numbers, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data was conducted using the non‐parameter rank sum test. Results:(1) Surgical situations. All patients in the two groups underwent laparos-copic right hemi-hepatectomy successfully, with the surgical margin as negative. The operation time, volume of intraoperative blood loss, time of dissection of the targeted hepatic pedicle, cases under-going dissection of the trunk of right anterior hepatic pedicle and its operation time, cases under-going dissection of the trunk of right posterior hepatic pedicle and its operation time, cases with hepatic pedicle injury, cases with hepatic tissue injury, cases with dissection space as large and small were 150.00(130.00)minutes, 100.00(100.00)mL, 472.00(201.00)seconds, 10 and 366.00(94.75)seconds, 9 and 564.00(138.50)seconds, 2, 2, 25, 0 in patients of the CPA group, versus 140.00(113.00)minutes, 100.00(125.00)mL, 670.00(107.00)seconds, 8 and 663.00(136.00)seconds, 7 and 783.00(189.00)seconds, 8, 5, 2, 19 in patients of the traditional approach group. There were significant differences in the time of dissection of the targeted hepatic pedicle, time of dissection of the trunk of right anterior hepatic pedicle, time of dissection of the trunk of right posterior hepatic pedicle, hepatic pedicle injury, dissection space between the two groups ( Z=-4.809, -3.254, -3.188, χ2=6.493, 34.314, P<0.05) and there was no significant difference in the operation time, volume of intraoperative blood loss, dissection of the trunk of right anterior hepatic pedicle, dissection of the trunk of right posterior hepatic pedicle, hepatic tissue injury between the two groups ( Z=-0.282, -0.412, χ2=0.095, 0.002, 1.976, P>0.05). (2) Postoperative situations. There was no patient under-going postoperative hemorrhage in both of the two groups. The alanine transaminase (ALT), aspartate transaminase (AST), total bilirubin (TBil) and prothrombin time (PT) at postoperative day 3, cases with postoperative biliary fistula, pathological type of tumor (hepatocellular carcinoma, intrahepatic cholangiocarcinoma) were 68.00(48.50)U/L, 52.00(35.50)U/L, 28.30(12.35)mmol/L, 12.40(2.40)seconds, 2, 21, 4 in patients of the CPA group. The above indicators were 58.00(25.00)U/L, 41.00(19.50)U/L, 26.80(14.25)mmol/L, 12.50(2.95)seconds, 5, 15, 2 in patients of the traditional approach group. There was no significant difference in the ALT, AST, TBil, PT at postoperative day 3, postoperative biliary fistula between the two groups ( Z=-1.218, -1.488, -0.205, -0.320, χ2=1.976, P>0.05), and there was no significant difference in the pathological type of tumor between the two groups ( P>0.05). Conclusion:Application of CPA for extrahepatic right hepatic pedicle dissection in MIALR is safe and feasible.

16.
Chinese Journal of Digestive Surgery ; (12): E001-E001, 2023.
Article in Chinese | WPRIM | ID: wpr-990658

ABSTRACT

Objective:To investigate the application value of cystic plate approach (CPA) for extrahepatic right hepatic pedicle dissection in minimally invasive anatomical hepatectomy (MIALR).Methods:The retrospective cohort study was conducted. The clinicopathological data of 42 patients with primary liver cancer who underwent laparoscopic right hemi-hepatectomy in Nanfang Hospital of Southern Medical University from August 2020 to August 2022 were collected. There were 36 males and 6 females, aged (55±13)years. Of the 42 patients, 25 cases undergoing CPA for extrahepatic right hepatic pedicle dissection were divided into the CPA group, and 17 cases undergoing traditional approach for extrahepatic right hepatic pedicle dissection were divided into the traditional approach group. Observation indicators: (1) surgical situations; (2) postoperative situations. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the t test. Measurement data with skewed distribution were represented as M( IQR), and comparison between groups was conducted using the Mann?Whitney U test. Count data were described as absolute numbers, and comparison between groups was conducted using the chi?square test or Fisher exact probability. Comparison of ordinal data was conducted using the non‐parameter rank sum test. Results:(1) Surgical situations. All patients in the two groups underwent laparoscopic right hemi-hepatectomy successfully, with the surgical margin as negative. The operative time, volume of intraoperative blood loss, time of dissection of the targeted hepatic pedicle, cases undergoing dissection of the trunk of right anterior hepatic pedicle and its operation time, cases undergoing dissection of the trunk of right posterior hepatic pedicle and its operation time, cases with hepatic pedicle injury, cases with hepatic tissue injury, cases with dissection space as large and small were 150.00(130.00)minutes, 100.00(100.00)mL, 472.00(201.00)seconds, 10 and 366.00(94.75)seconds, 9 and 564.00(138.50)seconds, 2, 2, 25, 0 in patients of the CPA group, versus 140.00(113.00)minutes, 100.00(125.00)mL, 670.00(107.00)seconds, 8 and 663.00(136.00)seconds, 7 and 783.00(189.00)seconds, 8, 5, 2, 19 in patients of the traditional approach group. There were significant differences in the time of dissection of the targeted hepatic pedicle, time of dissection of the trunk of right anterior hepatic pedicle, time of dissection of the trunk of right posterior hepatic pedicle, hepatic tissue injury, dissection space between the two groups ( Z=-4.809, -3.254, -3.188, χ2=6.493, 34.314, P<0.05) and there was no significant difference in the operation time, volume of intraoperative blood loss, dissection of the trunk of right anterior hepatic pedicle, dissection of the trunk of right posterior hepatic pedicle, hepatic tissue injury between the two groups ( Z=-0.282, -0.412, χ2=0.095, 0.002, 1.976, P>0.05). (2) Postoperative situations. There was no patient undergoing postoperative hemorrhage in both of the two groups. The alanine transaminase (ALT), aspartate transaminase (AST), total bilirubin (TBil) and prothrombin time (PT) at postoperative day 3, cases with postoperative biliary fistula, pathological type of tumor (hepatocellular carcinoma, intrahepatic cholangiocarcinoma) were 68.00(48.50)U/L, 52.00(35.50)U/L, 28.30(12.35)mmol/L, 12.40(2.40)seconds, 2, 21, 4 in patients of the CPA group. The above indicators were 58.00(25.00)U/L, 41.00(19.50)U/L, 26.80(14.25)mmol/L, 12.50(2.95)seconds, 5, 15, 2 in patients of the traditional approach group. There was no significant difference in the ALT, AST, TBil, PT at postoperative day 3, cases with postoperative biliary fistula between the two groups ( Z=-1.218, -1.488, -0.205, -0.320, χ2=1.976, P>0.05), and there was no significant difference in the pathological type of tumor between the two groups ( P>0.05). Conclusion:Application of CPA for extrahepatic right hepatic pedicle dissection in MIALR is safe and feasible.

17.
Journal of Medical Biomechanics ; (6): E556-E560, 2023.
Article in Chinese | WPRIM | ID: wpr-987985

ABSTRACT

Objective By comparing the fatigue strength of type A and type B locking compression plates (LCP) in distal femoral plate, a theoretical evaluation method was provided for type selection of bone plate when testing its bending strength and fatigue performance. Methods Through bending strength performance test and fatigue performance test on bone plates with different types, combined with ANSYS Workbench, the finite element analysis on total deformation, von Mises stress and fatigue service life of bone plates were conducted. Results The fatigue strength of type A plate was 30.7% higher than that of type B plate, the stress of type A plate was lower than that of type B plate, and the minimum fatigue service life of type A plate was 17% higher than that of type B plate. Conclusions The fatigue performance of type A plate is better than that of type B plate, so the failure possibility of type A plate was lower than that of type B plate.The results provide references for assisting selection of different bone plates when testing the performance of two newly developed bone plates.

18.
Journal of Medical Biomechanics ; (6): E104-E109, 2023.
Article in Chinese | WPRIM | ID: wpr-987921

ABSTRACT

Objective To study the stability of plate-assisted intramedullary nailing for fixing proximal third tibiafractures, compare and observe biomechanical characteristics of anterolateral or posteromedial plate-assisted intramedullary nailing after fixation of proximal third tibia fractures. Methods Eight artificial tibia of 4th-generation sawbones were divided into two groups based on location of the assisted plate, namely, anterolateral plate group and posteromedial plate group, with 4 specimens in each group. Each two locking bolts were fixed to theintramedullary nail proximally and distally, and each three bicortical screws were fixed to the plate proximally and distally. The specimens were osteotomized with a 10-mm defect which located 0. 5 cm to the proximal locking bolt of intramedullary nail or 5-6 cm distally to the knee joint line, in order to simulate an AO/ OTA 41-A2 type proximal third tibia fracture after fixation of intramedullary nail. After osteotomy was finished, axial compression test, three point bending test, cyclic loading and overstress test were conducted by mechanical testing machine. The results of axial stiffness and three-point stiffness between two groups were compared and analyzed. Results Axial compression test showed that the average axial stiffness in posteromedial plate group was lower than that in anterolateral plate group, but no significantly statistical differences were found between the two groups. Three point bending test showed that the average bending stiffness in posteromedial plate group was significantly higher than that in anterolateral plate group when stimulating either varus stress (plate located at pressure side of the fracture, t = 3. 679, P<0. 05) or valgus stress (plate located at tension side of the fracture, t = 8. 975, P<0. 05). Conclusions Plate-assisted intramedullary nailing for fixation of proximal third tibia fractures can minimize the angulation malalignment, improve the stability of nailed proximal tibial fragment and allow the early weight bearing. Both anterolateral and posteromedial plate-assisted intramedullary nail can provide satisfactory axial stability for proximal third tibia fractures, while posteromedial plate-assisted intramedullary nail shows better bending stability than anterolateral plate in countering varus or valgus stress deformity. This study provides an essential basis for clinical decision making about plate-assisted intramedullary nailing for fixing proximal third tibia fractures.

19.
China Journal of Orthopaedics and Traumatology ; (12): 255-261, 2023.
Article in Chinese | WPRIM | ID: wpr-970858

ABSTRACT

OBJECTIVE@#To investigate the biomechanical characteristics of different internal fixations for Pauwels type Ⅲ femoral neck fracture with defect, and provide reference for the treatment of femoral neck fracture.@*METHODS@#Three-dimensional (3D) finite element models of femoral neck fractures were established based on CT images, including fracture and fracture with defects. Four internal fixations were simulated, namely, inverted cannulated screw(ICS), ICS combined with medial buttress plate, the femoral neck system (FNS) and FNS combined with medial buttress plate. The von Mises stress, model stiffness and fracture displacements of fracture models under 2 100 N axial loads were measured and compared.@*RESULTS@#When femoral neck fracture was fixed by ICS and FNS, the peak stress was mainly concentrated on the surface of the screw near the fracture line, and the peak stress of FNS is higher than that of ICS;When the medial buttress plate was combined, the peak stress was increased and transferred to medial buttress plate, with more obvious of ICS fixation. For the same fracture model, the stiffness of FNS was higher than that of ICS. Compared with femoral neck fracture with defects, fracture model showed higher stiffness in the same internal fixation. The use of medial buttress plate increased model stiffness, but ICS increased more than FNS. The fracture displacement of ICS model exceeded that of FNS.@*CONCLUSION@#For Pauwels type Ⅲ femoral neck fracture with defects, FNS had better biomechanical properties than ICS. ICS combined with medial buttress plate can better enhance fixation stability and non-locking plate is recommended. FNS had the capability of shear resistance and needn't combine with medial buttress plate.


Subject(s)
Humans , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Bone Screws , Bone Plates , Biomechanical Phenomena , Finite Element Analysis
20.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Article in Chinese | WPRIM | ID: wpr-970852

ABSTRACT

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Subject(s)
Middle Aged , Humans , Treatment Outcome , Blood Loss, Surgical , Retrospective Studies , Fracture Fixation, Internal/methods , Femoral Neck Fractures/surgery , Bone Screws
SELECTION OF CITATIONS
SEARCH DETAIL